The Influence Of The Location Of Concrete Joints And Longitudinal Reinforcement On T-Beams At A Distance Of A Quarter Of The Span
DOI:
https://doi.org/10.52722/q10rdf81Abstrak
The purpose of this study is to compare continuous beams (CB) with beams with concrete and reinforcement joints spaced at 1/4 span to analyze the flexural and shear behavior of reinforced concrete T-beams. The bending moment, shear strength, and strain on each beam are measured experimentally as part of the procedures. The test findings demonstrate that the T-beam with no joints has a larger flexural capacity, with a maximum bending moment of 28905926.28 Nmm and beginning cracking at a weight of 1543.08 kg.
Unduhan
Referensi
[1] Departemen Pekerjaan Umum, 2018, Spesifikasi Umum Revisi 2. Jakarta: Pusat Litbang Prasarana Transportasi Badan penelitian Dan pengembangan.
[2] Badan Standardisasi Nasional. 2002. Tata Cara Perencanaan Ketahanan Gempa untuk Bangunan Gedung SNI 03-1726-2002. Bandung : BSN
[3] Febrianto .A.S.P.2013. Pengaruh Sambungan Beton Dan Tulangan Logitudinal Pada Jarak Seper-Lima Bentang Terhadap Kekuatan Balok. Skripsi tidak diterbitkan. Malang: FTSP ITN.
[4] Imran, I., Kamaludin & Hanafiah, Perilaku Sambungan Antara Elemen Beton
[5] Manaha,Y.P. 2009. Efektifitas Pengekangan Fine Mesh Terhadap Peningkatan Daktilitas Kolom Beton Bertulang di Daerah Gempa Kuat, DIPA 2009 Nomor : 091/SP2H/PP/DP2M/IV/2009 Direktorat Jenderal Pendidikan Tinggi Departemen Pendidikan Nasional.
[6] Nainggolan T.H, Manaha Y.P, Priskasari E., Pengaruh Sambungan Beton dan Tulangan Longitudinal Terhadap Kekuatan Balok SRPMK, buku penelitian.
[7] Nawy, E.G.Tanpa Tahun . Beton Bertulang Sebuah Pendekatan Mendasar (Jilid 1).Terjemahan Tavio & Kusuma, B. 2010. Surabaya: ITS Press.
[8] Ningsih. 2004. Penggunaan Pasak Kayu Bentuk Ekor Burung Sebagai Sambungan Momen dan Geser Pada Balok Kayu
[9] Permana, L.C. 2013.Pengaruh Sambungan Beton Dan Tulangan Logitudinal Pada Jarak Seper-Empat Bentang Terhadap Kekuatan Balok. Skripsi tidak diterbitkan. Malang: FTSP ITN.
[10] Priskasari, E. 2010. Kekuatan Lekatan (Bond) dan Panjang Penyaluran Tulangan Cold Rolled & Twisted Bar Pada Beton Mutu Tinggi. Penelitian Hibah Bersaing.
[11] Purwono, R. Tavio. Imran, I. & Raka, I.G.P. 2007. Tata Cara Perhitungan Struktur Beton untuk Bangunan Gedung SNI 03-2847-2002 dilengkapi Penjelasan (S-2002). Surabya: ITS Press.
[12] Putra .M. V. M.2013. Pengaruh Sambungan Beton Dan Tulangan Logitudinal Pada Jarak Seper-Enam Bentang Terhadap Kekuatan Balok. Skripsi tidak diterbitkan. Malang: FTSP ITN